Description
Product overview
TZ‑8108 vertical limit switch is equipped with adjustable long roller lever actuator, SPDT 1NO+1NC quick‑action silver alloy contacts. It converts mechanical stroke movement into electrical signal for position limiting, stroke control and safety interlock. Widely applied for elevator, hoisting machinery, conveyor belts, machine tools, packaging and automation production lines. Zinc‑alloy housing delivers high mechanical impact resistance. IP65 dust‑proof, water‑splash‑proof and oil‑proof for harsh industrial workshop environment
‑ Long adjustable metal roller lever, flexible angle adjustment
‑ 1NO+1NC fast‑action momentary silver alloy contacts
‑ Robust zinc‑alloy housing, anti‑impact & anti‑deformation
‑ IP65 protection grade, dust‑proof, splash‑water resistant, oil‑proof
‑ PG11 cable‑gland sealing structure for stable wiring
‑ Large over‑travel, overload‑resistant mechanical structure
‑ Double‑spring internal mechanism for long service lifespan
‑ CE certified, conform to IEC/EN60947‑5‑1 standard
Characteristics
|
Operation speed |
0.5mm-50cm/sec |
|
Operating frequency |
Mechanical: 120 operations/m, Electrical: 30 operations/m |
|
Contact resistance |
25mΩ max. (initial value) |
|
Insulation resistance |
100mΩ min. (Below 500VDC) |
|
Dielectric strength |
1000VAC, 50/60HZ for 1 minute between noncontinuious terminal |
|
|
1500VAC, 50/60 HZ for 1 minute between load current and no load current |
|
|
1500VAC, 50/60 HZ for 1 minute between each terminal and ground |
|
Vibration |
10-55HZ,1.5mm double amplitude |
|
Shock |
Mechanical durability 1000m/ sec2 (about 100G'S) Malfunction: 300m/ sec2 (about 30G'S) |
|
Ambient temperature |
-5℃ to +65℃ |
|
Humidity |
<95% RH |
|
Life |
Mechanical: 10,000,000 operations above Electrical: 500,000 operations above |
|
Weight |
About 130 to 190g |
|
IEC |
IP65 |
Ratings
|
Rated Voltage |
Noninductive Load |
Inductive Load |
||||||
|
Resistance Load |
Lamp Load |
Inductive Load |
Motor Load |
|||||
|
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
|
125VAC |
5 |
5 |
1.5 |
0.7 |
3 |
3 |
2 |
1 |
|
8VDC |
5 |
5 |
3 |
3 |
5 |
4 |
3 |
3 |
|
Inrush Current |
N.C: below 24A, N.O: below 12A |
|||||||
NOTES:
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has
an inrush current of 6 times the steady-state current.
|
|
TZ-8104 |
TZ-8108 |
TZ-8107 |
TZ-8111 |
TZ-8112/8122 |
TZ-8166/8167/8168/8169 |
|
OF Max. |
750g |
750g |
750g |
900g |
900g |
150g |
|
RF Min. |
100g |
100g |
100g |
150g |
150g |
- |
|
PT Max. |
20º |
20 º |
20 º |
1.5mm |
1.5mm |
30mm |
|
OT Min. |
50 º |
50 º |
50 º |
4mm |
4mm |
- |
|
MD Max. |
12 º |
12 º |
12 º |
1mm |
1mm |
- |
|
OP |
- |
- |
- |
26 ± 0.8mm |
37 ± 0.8mm |
- |