Description
Product overview
Features:
Double circuit type of limit switch High mechanical strength, consists of intensive plastic and aluminum cast Small size, water-proof and oil-proof construction Built-in contact box has double-spring and long mechanical life Smooth operation with larger over travel distance Conduit design for convenient cabling Various actuators for convenient applications
Model Designation
|
No
|
Item
|
Code
|
Description
|
Forced disconnection Yes/No
|
|
1
|
Product series
|
TZ-8
|
Design code
|
|
|
2
|
Head structure
|
104
|
Plastic roller swing rod type
|
Only NC end has forced disconnection
|
|
105
|
Metal roller swing rod type
|
Only NC end has forced disconnection
|
||
|
107
|
Adjustable rod swing rod type
|
Only NC end has forced disconnection
|
||
|
108
|
Adjustable swing rod plastic roller type
|
Only NC end has forced disconnection
|
||
|
109
|
Adjustable swing rod metal roller type
|
Only NC end has forced disconnection
|
||
|
111
|
Plunger type
|
|
||
|
111M
|
Plunger type(Metal head)
|
|
||
|
112
|
Cross wheel plunger type
|
|
||
|
112M
|
Cross wheel plunger type (Metal head)
|
|
||
|
122
|
Vertical wheel plunger type
|
|
||
|
122M
|
Vertical wheel plunger type (Metal head)
|
|
||
|
166
|
Plastic rod coil spring type
|
|
||
|
167
|
Coil spring type
|
|
||
|
168
|
Metal rod coil spring type
|
|
||
|
169
|
Tentacle type
|
|
||
|
108H
|
Adjustable swing rod rubber roller type
|
Only NC end has forced disconnection
|
||
|
3
|
Outgoing type
|
None
|
Rubber tail sleeve
|
|
Specifications
|
Operation Speed
|
5mm-0.5m/s
|
|
Operating Frequency
|
Electrical: 30 operations/min
|
|
Contact Resistance
|
25mΩ max. (initial value)
|
|
Insulation Resistance
|
100mΩ min. (below 500VDC)
|
|
|
1000VAC,50/60Hz for 1 minute between terminals of the same polarity
|
|
1500VAC,50/60Hz for 1 minute between current-carrying and non-current-carrying metal parts
|
|
|
1500VAC,50/60Hz for 1 minute between each terminal and ground
|
|
|
Vibration
|
10-55Hz, 1.5mm double ampliude
|
|
Shock
|
Mechanical durable: 1,000m/Sec² (about 100G'S)
Malfunction: 300m/Sec² (about 30G'S)
|
|
Ambient Temperature
|
Using: -20~+70℃ (With no icing)
|
|
Humidity
|
<95% RH
|
|
Electrical Life
|
500,000 operations above
|
|
Degree of Protection
|
IP65
|
Ratings
|
Rated Voltage
|
Noninductive Load (A)
|
Inductive Load (A)
|
||||||
|
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
|||||
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
|
|
AC 125
|
6
|
1.5
|
0.7
|
3
|
2
|
1
|
||
|
AC 250
|
6
|
1
|
0.5
|
3
|
1.5
|
0.8
|
||
|
DC 12
|
6
|
3
|
4
|
3
|
||||
|
DC 24
|
6
|
3
|
4
|
3
|
||||
|
DC 125
|
0.4
|
0.2
|
-
|
-
|
-
|
|||
|
DC 50
|
0.4
|
0..2
|
-
|
-
|
-
|
|||
|
Surge current
|
NC
|
Max. 24A
|
||
|
NO
|
Max. 12A
|
|||