Product overview
HL‑5100 sealed plunger type limit switch is compact vertical travel control component for industrial automation. It comes with fully‑sealed plunger actuator, good dust‑proof and splash‑proof capability.
High‑quality silver SPDT (1NO+1NC) contacts provide stable snap‑action signal switching. Robust metal shell achieves IP65 protection grade, perfectly fits harsh workshop working conditions. Compact vertical structure enables simple installation and wiring.
- Sealed plunger actuator for direct push triggering
- IP65 waterproof & dustproof for tough industrial environment
- High‑quality silver SPDT contacts for reliable switching
- 10A 380V rated for heavy‑duty control application
- Sturdy metal shell, anti‑impact and anti‑vibration
- Widely used in automation, machine tools and lifting equipment
- Small footprint, convenient installation & maintenance
Specifications
|
Operation speed
|
5mm-0.5m/s
|
|||
|
Operating frequency
|
Electical: 30 operations/min
|
|||
|
Contact rsistance
|
25mΩ max. (initial value)
|
|||
|
Insulation resistance
|
100mΩ min. (below 500VDC)
|
|||
|
Rated insulation voltage
|
380V
|
|||
|
Rated impulse withstand voltage
|
2.5kV
|
|||
|
Convention free air heating current
|
10A
|
|||
|
|
1000VAC, 50/60HZ for 1 minute between noncontinuious terminal
|
|||
|
1500VAC, 50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts
|
||||
|
1500VAC, 50/60 Hz for 1 minute between each terminal and ground
|
||||
|
Vibration
|
10~55Hz,1.5mm double amplitude
|
|||
|
Shock
|
Mechanical durable: 1,000m/Sec² (about 100G'S)
Malfunction: 300m/Sec² (about 30G'S)
|
|||
|
Ambient temperature
|
Using: -20~+70℃ (With no icing)
|
|||
|
Humidity
|
<95% RH
|
|||
|
Electrical life
|
More than 300,000 times (AC250V, 6A, resistive load)
|
|||
|
Protection level
|
IP65
|
|||
Ratings
|
Rated Voltage
|
Noninductive Load (A)
|
Inductive Load (A)
|
||||||
|
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
|||||
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
|
|
125VAC
|
5
|
5
|
1.5
|
0.7
|
3
|
3
|
2
|
1
|
|
250VAC
|
5
|
5
|
0.7
|
0.5
|
3
|
3
|
1.5
|
0.8
|
|
8VDC
|
5
|
5
|
3
|
3
|
5
|
4
|
3
|
3
|
|
14VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
30VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
125VDC
|
0.4
|
0.4
|
|
|
|
|
|
|
|
250VDC
|
0.2
|
0.2
|
|
|
|
|
|
|
|
Inrush Current
|
N.C: below 24A, N.O: below 12A
|
|||||||
3.Product with spring, its usable range of operating part is within one third of whole spring length from the front end of spring.