Description
Product overview
HL‑5300 coil spring type limit switch is vertical travel control component for industrial automation. The flexible coil‑spring actuator can accept multi‑directional contact force, tolerates offset triggering.
High‑quality silver SPDT (1NO+1NC) contacts provide reliable snap‑action signal switching. Robust metal shell reaches IP65 protection grade, effectively resisting dust and water splash for harsh workshop environments. Compact vertical design allows quick installation and simple wiring.
- Flexible coil spring actuator supports multi‑direction triggering
- Tolerates offset contact and mis‑alignment installation
- IP65 waterproof & dustproof for tough industrial conditions
- Premium silver SPDT contacts for stable signal switching
- 10A 380V rated for heavy‑duty control applications
- Sturdy metal shell, anti‑impact and anti‑vibration
- Widely used in automation, machine tools and lifting equipment
- Compact size, convenient installation & maintenance
Specifications
|
Operation speed
|
5mm-0.5m/s
|
|||
|
Operating frequency
|
Electical: 30 operations/min
|
|||
|
Contact rsistance
|
25mΩ max. (initial value)
|
|||
|
Insulation resistance
|
100mΩ min. (below 500VDC)
|
|||
|
Rated insulation voltage
|
380V
|
|||
|
Rated impulse withstand voltage
|
2.5kV
|
|||
|
Convention free air heating current
|
10A
|
|||
|
|
1000VAC, 50/60HZ for 1 minute between noncontinuious terminal
|
|||
|
1500VAC, 50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts
|
||||
|
1500VAC, 50/60 Hz for 1 minute between each terminal and ground
|
||||
|
Vibration
|
10~55Hz,1.5mm double amplitude
|
|||
|
Shock
|
Mechanical durable: 1,000m/Sec² (about 100G'S)
Malfunction: 300m/Sec² (about 30G'S)
|
|||
|
Ambient temperature
|
Using: -20~+70℃ (With no icing)
|
|||
|
Humidity
|
<95% RH
|
|||
|
Electrical life
|
More than 300,000 times (AC250V, 6A, resistive load)
|
|||
|
Protection level
|
IP65
|
|||
Ratings
|
Rated Voltage
|
Noninductive Load (A)
|
Inductive Load (A)
|
||||||
|
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
|||||
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
|
|
125VAC
|
5
|
5
|
1.5
|
0.7
|
3
|
3
|
2
|
1
|
|
250VAC
|
5
|
5
|
0.7
|
0.5
|
3
|
3
|
1.5
|
0.8
|
|
8VDC
|
5
|
5
|
3
|
3
|
5
|
4
|
3
|
3
|
|
14VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
30VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
125VDC
|
0.4
|
0.4
|
|
|
|
|
|
|
|
250VDC
|
0.2
|
0.2
|
|
|
|
|
|
|
|
Inrush Current
|
N.C: below 24A, N.O: below 12A
|
|||||||
NOTES:
1.Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 msec. max. (DC).
2.Lamp load has an inrush current of 10 times the steady-state current, while motor load has an inrush current of 6 times the steady-state current.
3.Product with spring, its usable range of operating part is within one third of whole spring length from the front end of spring.
3.Product with spring, its usable range of operating part is within one third of whole spring length from the front end of spring.