Description
Product overview
HL‑5330 palp‑type vertical limit switch is a compact travel control component for industrial automation. The flexible palp actuator can receive force from multiple directions, allowing oblique and offset triggering without damaging the switch.
Built‑in premium silver SPDT (1NO+1NC) contacts deliver fast snap‑action switching for reliable signal feedback. Heavy‑duty metal shell achieves IP65 protection against dust, water splash and oil mist, well‑suited for harsh workshop conditions. Compact vertical structure supports quick mounting and convenient wiring.
- Flexible palp actuator accepts multi‑directional offset triggering
- Prevent switch damage from misaligned mechanical impact
- IP65 waterproof & dustproof for tough industrial workshop
- High‑quality silver SPDT contacts for stable signal switching
- 10A 380V heavy‑duty rated capacity
- Sturdy metal shell, anti‑impact and anti‑vibration
- Perfect for lifting, conveyor and general automation equipment
- Small footprint, easy installation and maintenance
Specifications
|
Operation speed
|
5mm-0.5m/s
|
|||
|
Operating frequency
|
Electical: 30 operations/min
|
|||
|
Contact rsistance
|
25mΩ max. (initial value)
|
|||
|
Insulation resistance
|
100mΩ min. (below 500VDC)
|
|||
|
Rated insulation voltage
|
380V
|
|||
|
Rated impulse withstand voltage
|
2.5kV
|
|||
|
Convention free air heating current
|
10A
|
|||
|
|
1000VAC, 50/60HZ for 1 minute between noncontinuious terminal
|
|||
|
1500VAC, 50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts
|
||||
|
1500VAC, 50/60 Hz for 1 minute between each terminal and ground
|
||||
|
Vibration
|
10~55Hz,1.5mm double amplitude
|
|||
|
Shock
|
Mechanical durable: 1,000m/Sec² (about 100G'S)
Malfunction: 300m/Sec² (about 30G'S)
|
|||
|
Ambient temperature
|
Using: -20~+70℃ (With no icing)
|
|||
|
Humidity
|
<95% RH
|
|||
|
Electrical life
|
More than 300,000 times (AC250V, 6A, resistive load)
|
|||
|
Protection level
|
IP65
|
|||
Ratings
|
Rated Voltage
|
Noninductive Load (A)
|
Inductive Load (A)
|
||||||
|
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
|||||
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
|
|
125VAC
|
5
|
5
|
1.5
|
0.7
|
3
|
3
|
2
|
1
|
|
250VAC
|
5
|
5
|
0.7
|
0.5
|
3
|
3
|
1.5
|
0.8
|
|
8VDC
|
5
|
5
|
3
|
3
|
5
|
4
|
3
|
3
|
|
14VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
30VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
125VDC
|
0.4
|
0.4
|
|
|
|
|
|
|
|
250VDC
|
0.2
|
0.2
|
|
|
|
|
|
|
|
Inrush Current
|
N.C: below 24A, N.O: below 12A
|
|||||||
3.Product with spring, its usable range of operating part is within one third of whole spring length from the front end of spring.