Description
Product overview
HL‑5391 rubber roller adjustable swing‑rod vertical limit switch is a reliable travel control component for industrial automation. It features adjustable swing rod fitted with soft rubber roller. The swing‑rod angle can be adjusted on‑site to satisfy different installation requirements.
Rubber roller design cushions mechanical impact, lowers operating noise and extends service life of actuator. High‑quality silver SPDT (1NO+1NC) contacts provide fast snap‑action signal switching. Heavy‑duty metal shell reaches IP65 protection grade, resisting dust, water splash and oil mist in harsh workshop environments. Compact vertical structure enables quick installation and simple wiring.
- Adjustable swing rod with rubber roller for angle flexible adjustment
- Rubber roller cushions impact, lowers noise and reduces abrasion
- IP65 waterproof & dustproof for tough industrial workshop conditions
- Premium silver SPDT contacts for stable snap‑action switching
- 10A 380V heavy‑duty electrical rating
- Sturdy metal shell, anti‑impact and anti‑vibration
- Ideal for lifting equipment, conveyors and automation machines
- Compact size, convenient installation and maintenance
Specifications
|
Operation speed
|
5mm-0.5m/s
|
|||
|
Operating frequency
|
Electical: 30 operations/min
|
|||
|
Contact rsistance
|
25mΩ max. (initial value)
|
|||
|
Insulation resistance
|
100mΩ min. (below 500VDC)
|
|||
|
Rated insulation voltage
|
380V
|
|||
|
Rated impulse withstand voltage
|
2.5kV
|
|||
|
Convention free air heating current
|
10A
|
|||
|
|
1000VAC, 50/60HZ for 1 minute between noncontinuious terminal
|
|||
|
1500VAC, 50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts
|
||||
|
1500VAC, 50/60 Hz for 1 minute between each terminal and ground
|
||||
|
Vibration
|
10~55Hz,1.5mm double amplitude
|
|||
|
Shock
|
Mechanical durable: 1,000m/Sec² (about 100G'S)
Malfunction: 300m/Sec² (about 30G'S)
|
|||
|
Ambient temperature
|
Using: -20~+70℃ (With no icing)
|
|||
|
Humidity
|
<95% RH
|
|||
|
Electrical life
|
More than 300,000 times (AC250V, 6A, resistive load)
|
|||
|
Protection level
|
IP65
|
|||
Ratings
|
Rated Voltage
|
Noninductive Load (A)
|
Inductive Load (A)
|
||||||
|
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
|||||
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
|
|
125VAC
|
5
|
5
|
1.5
|
0.7
|
3
|
3
|
2
|
1
|
|
250VAC
|
5
|
5
|
0.7
|
0.5
|
3
|
3
|
1.5
|
0.8
|
|
8VDC
|
5
|
5
|
3
|
3
|
5
|
4
|
3
|
3
|
|
14VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
30VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
|
125VDC
|
0.4
|
0.4
|
|
|
|
|
|
|
|
250VDC
|
0.2
|
0.2
|
|
|
|
|
|
|
|
Inrush Current
|
N.C: below 24A, N.O: below 12A
|
|||||||
3.Product with spring, its usable range of operating part is within one third of whole spring length from the front end of spring.