Description
Product overview
LMF15 series industrial square inductive proximity sensor adopts eddy‑current inductive principle for non‑contact detection of metallic objects. It features non‑flush mounting with 15 mm long rated sensing distance. Multiple output options support various industrial automation control systems. Built‑in reverse‑polarity, surge and short‑circuit protection delivers strong anti‑interference capability. IP67 protection grade ensures stable operation in dusty, oily and moist workshop environments. Red LED indicator shows real‑time working‑status. Widely applied for position limit, pulse counting and metal detection for heavy‑duty automation machinery.
‑ Square housing, non‑flush installation, rated sensing distance: 15 mm
‑ Multiple output options: DC3‑wire NPN / PNP (NO / NC / NO+NC), AC 2‑wire, Relay output
‑ Integrated reverse‑polarity, surge & short‑circuit protection
‑ Red LED operation status indicator
‑ IP67 dust‑proof & water‑proof rating
‑ Wide working temperature:‑25℃ ~ +75℃
‑ CE certified, high‑strength ABS plastic housing
‑ Long detection range, suitable for heavy‑duty industrial automation sites
| INDUCTIVE PROXIMITY SWITCH | |||||
| Structural category | Angular column type | ||||
| Outward appearance code | LMF15 | ||||
| Appearance | ![]() |
||||
| Dimension | ![]() |
||||
| Flush | Detection distance | 2mm | |||
| NPN | NO | 3002NA | |||
| DC | NC | 3002NB | |||
| 6 | NO+NC | 3002NC | |||
| ~ | PNP | NO | 3002PA | ||
| 36 | NC | 3002PB | |||
| V | NO+NC | 3002PC | |||
| two wire system | NO | 3002LA | |||
| NC | 3002LB | ||||
| AC | SRC Control label silicon | NO | 2002A | ||
| 90 | NC | 2002B | |||
| ~250 | NO+NC | ||||
| V | Relay output | ||||
| Non-flush | Detection distance | 4mm | |||
| NPN | NO | 3004NA | |||
| NC | 3004NB | ||||
| DC | NO+NC | 3004NC | |||
| 6 | PNP | NO | 3004PA | ||
| ~ | NC | 3004PB | |||
| 36 | NO+NC | 3004PC | |||
| V | two wire system | NO | 3004LA | ||
| NC | 3004LB | ||||
| AC | SRC Control label silicon | NO | 2004A | ||
| 90 | NC | 2004B | |||
| ~250 | NO+NC | ||||
| V | Relay output | ||||
| Control output | DC | 200mA | |||
| SCR/Relay | 300mA/1A | ||||
| Output voltage dropDC/AC | DC<2V , DC(Two wire system)<3.9V , AC<10mA | ||||
| Consumption current | DC<15mA AC<10mA | ||||
| Standard detected object | 15×15×F(A3 iron) | ||||
| Repeated precision | 0.02 | ||||
| DC/AC Response frequency | 200Hz/15Hz | ||||
| Working environment temperature | -25ºC~75ºC | ||||
| Insulation resistance | 50MΩ | ||||
| Shell material | ABS Resin | ||||
| Protection grade | IEC standard IP67 | ||||
| Altemative model at home and abroad | ST-F- | ||||
Wiring diagram