Description
Product overview
LMF55 series angular‑column square inductive proximity switch adopts eddy‑current inductive principle for non‑contact metal object detection. Non‑flush mounting with long 25 mm rated sensing distance. Optimized circuit design delivers stable signal output for long‑range metal presence monitoring. Multiple output options fit different industrial automation control systems. Built‑in reverse‑polarity, surge and short‑circuit protection ensures excellent anti‑interference and anti‑vibration performance. IP67 protection grade performs reliably under dusty and oily workshop environments. Red LED indicator shows real‑time working‑status. Widely used for remote position‑limit detection, object counting and metal target sensing for heavy‑duty automation machinery.
‑ Angular‑column square housing, non‑flush installation, rated sensing distance: 25 mm
‑ Extra long detection distance, suitable for installation space with large clearance
‑ Multiple output options: DC3‑wire NPN / PNP (NO / NC / NO+NC), AC 2‑wire, Relay output
‑ Integrated reverse‑polarity, surge & short‑circuit protection
‑ Red LED working‑status indicator
‑ IP67 dust‑proof & water‑proof rating
‑ Wide operating temperature:‑25℃ ~ +75℃
‑ CE certified, high‑strength ABS resin housing
‑ Stable long‑range detection performance for heavy‑duty industrial‑field applications
| INDUCTIVE PROXIMITY SWITCH | |||||
| Structural category | Plane installation type | ||||
| Outward appearance code | LMF55 | ||||
| Appearance | ![]() |
||||
| Dimension | ![]() |
||||
| Flush | Detection distance | ||||
| NPN | NO | ||||
| DC | NC | ||||
| 6 | NO+NC | ||||
| ~ | PNP | NO | |||
| 36 | NC | ||||
| V | NO+NC | ||||
| two wire system | NO | ||||
| NC | |||||
| AC | SRC Control label silicon | NO | |||
| 90 | NC | ||||
| ~250 | NO+NC | ||||
| V | Relay output | ||||
| Non-flush | Detection distance | 25mm | |||
| NPN | NO | 3025NA | |||
| NC | 3025NB | ||||
| DC | NO+NC | 3025NC | |||
| 6 | PNP | NO | 3025PA | ||
| ~ | NC | 3025PB | |||
| 36 | NO+NC | 3025PC | |||
| V | two wire system | NO | |||
| NC | |||||
| AC | SRC Control label silicon | NO | 2025A | ||
| 90 | NC | 2025B | |||
| ~250 | NO+NC | 2025C | |||
| V | Relay output | ||||
| Control output | DC | 300mA | |||
| SCR/Relay | 500mA/2A | ||||
| Output voltage dropDC/AC | DC<3V , DC(Two wire system)<3.9 , AC<10V | ||||
| Consumption current | DC<15mA AC<10mA | ||||
| Standard detected object | 70×70×1(A3 iron) | ||||
| Repeated precision | 0.05 | ||||
| DC/AC Response frequency | 200Hz/25Hz | ||||
| Working environment temperature | -25ºC~75ºC | ||||
| Insulation resistance | 50MΩ | ||||
| Shell material | ABS Resin | ||||
| Protection grade | IEC standard IP67 | ||||
| Altemative model at home and abroad | |||||
Wiring diagram