Description
Product overview
LMF80 series large‑size angular‑column square inductive proximity sensor adopts eddy‑current inductive principle for non‑contact metal object detection. Non‑flush mounting with ultra‑long 60 mm rated sensing distance. Optimized large‑range sensing circuit ensures stable trigger signal for heavy‑duty industrial sites with large installation clearance. Multiple output options match diverse industrial automation control systems. Built‑in reverse‑polarity, surge and short‑circuit protection delivers outstanding anti‑interference and anti‑vibration performance. IP67 protection grade resists dust and oil splashes in harsh workshop environments. Red LED indicator shows real‑time working‑status. Widely used for long‑gap position‑limit detection, heavy‑machinery position feedback and metal target sensing for large‑scale automation equipment.
‑ Large angular‑column square housing, non‑flush installation, rated sensing distance: 60 mm
‑ Ultra‑long detection range, designed for applications with large mounting clearance
‑ Multiple output options: DC3‑wire NPN / PNP (NO / NC / NO+NC), AC 2‑wire, Relay output
‑ Integrated reverse‑polarity, surge & short‑circuit protection
‑ Red LED working‑status indicator
‑ IP67 dust‑proof & water‑proof rating
‑ Wide operating temperature:‑25℃ ~ +75℃
‑ CE certified, high‑strength impact‑resistant ABS resin housing
‑ Reliable ultra‑long‑distance detection performance for heavy‑duty industrial field
| INDUCTIVE PROXIMITY SWITCH | |||||
| Structural category | Angular column type | ||||
| Outward appearance code | LMF80 | ||||
| Appearance | ![]() |
||||
| Dimension | ![]() |
||||
| Electrical design | AC/DC |
| Output function | Normally open/closed programmable |
| Operating voltage [V] | 20...250 AC/DC |
| Load current (continuous) [mA] Current rating (continuous) [mA] | 200 AC, 100 DC *) |
| Load current (maximum) [mA] Current rating (peak) [mA] | I: 2.2 A (20 ms / 0.5 Hz) |
| Minimum load current [mA] Minimum load current [mA] | 5 |
| Short - circuit proof | no |
| Reverse polarity protection | no |
| Overload protection | no |
| Voltage drop [V] | AC 6.5 / DC 6 |
| Leakage current [mA] | < 2.5 (AC 250 V) / < 1.3 (AC 110 V) / < 0.8 (DC 24 V) |
| Releasing distance [mm]/Sn Releasing distance [mm]/Sn | 60 ± 10 % |
| Operating distance [mm] Operating distance [mm] | 0...48.6 |
| Switch - point drift [%] Switch - point drift [%] | -10...10 |
| Hysteresis [% of Sr] Hysteresis [% of Sr] | 1...15 |
| Switching frequency [Hz] | 4 |
| Correction factors | mild steel = 1 / stainless steel approx. 0.7 / brass approx. 0.4 / aluminum approx. 0.3 / copper approx. 0.2 |
| Ambient temperature [°C] | -20...60 **) |
| Protection class | IP 65, II |
| EMC/EMI compliance | EN 60947-5-2 |
| Marking of the unit | II 3D Ex tD A22 IP65 T90 °C X |
| Housing materials | 460 |
| Function display | PPE |
| Switching status LED | yellow |
| Connection | Terminals up to 2.5 mm²; cable diameter 5.5...13 mm, cable gland M20 x 1.5 |
| Torque for tightening the cable gland for the voltage - surge arrester [Nm] | 3.5 |
| Weight [kg] | 0.454 |
Wiring diagram