Description
Product overview
G12‑series compact M12 threaded cylindrical photoelectric sensor adopts modulated infrared light source, available in through‑beam, retro‑reflective and diffuse‑reflective detection modes. Compact M12 threaded body saves installation space for narrow‑space automation equipment. PBT plastic housing with epoxy potting sealing achieves IP67 protection grade against dust, water splash and oil contamination. Built‑in sensitivity adjustment potentiometer, Light‑ON / Dark‑ON function selectable. DC 3‑wire NPN / PNP output with reverse‑polarity and short‑circuit protection. Red LED indicator displays real‑time working‑status. Widely applied for small‑object detection, position triggering, counting and object‑presence monitoring in packaging machinery, textile equipment, conveyor‑lines and compact‑layout automation facilities.
‑ Compact M12 threaded cylindrical housing, install with lock‑nut, fit for limited‑space mounting
‑ Three detection modes optional: Through‑beam / Retro‑reflective / Diffuse‑reflective
‑ Modulated infrared LED light source, strong anti‑ambient‑light‑interference performance
‑ Sensitivity adjustable potentiometer; Light‑ON / Dark‑ON switchable
‑ DC 3‑wire NPN / PNP output, max load current 200 mA
‑ Built‑in reverse‑polarity & short‑circuit protection
‑ PBT engineering‑plastic housing, IP67 dust‑proof & splash‑proof
‑ Red LED working‑status indicator
‑ Standard 2‑meter pre‑wired PVC cable
‑ Supply voltage: DC10‑30 VDC
‑ Wide operating temperature:‑25℃ ~ +55℃
‑ CE certified, non‑contact detection, long service‑life
‑ Perfect for compact‑structure industrial‑automation detection projects
| Structural category | Photoelectric switch | ||||
| Outward appearance code | G12 | ||||
| Appearance | ![]() |
||||
| Dimension | ![]() |
||||
| Diffuse type | Detection distance | 0-8cm | |||
| DC | NPN | NO | 3A08NA | ||
| 10 | NC | 3A08NB | |||
| ~ | NO+NC | ||||
| 30 | PNP | NO | 3A08PA | ||
| V | NC | 3A08PB | |||
| NO+NC | |||||
| 90~ | SRC Control label silicon | NO | |||
| 250 | NC | ||||
| V AC | Relay output | ||||
| Retroreflictive | Detection distance | 1m | |||
| NPN | NO | 3B1NA | |||
| DC | NC | 3B1NB | |||
| 10 | NO+NC | ||||
| ~ | PNP | NO | 3B1PA | ||
| 30 | NC | 3B1PB | |||
| V | NO+NC | ||||
| 90~ | SRC Control label silicon | NO | |||
| 250 | NC | ||||
| V AC | Relay output | ||||
| Trough beam | Detection distance | 3m | |||
| NPN | NO | 3C3NA | |||
| DC | NC | 3C3NB | |||
| 10~ | NO+NC | ||||
| 30 | PNP | NO | 3C3PA | ||
| V | NC | 3C3PB | |||
| NO+NC | |||||
| 90~ | SRC Control label silicon | NO | |||
| 250 | NC | ||||
| V AC | Relay output | ||||
| DC/SCR Control output | DC:200mA | ||||
| DC/AC Consumption current | DC<15mA | ||||
| DC/AC Response time | DC<2ms | ||||
| Directional angle | 3°-10° | ||||
| Detected object | transparent of opaque body | ||||
| Working environment temperature | -25ºC~55ºC | ||||
| Intensity of illumination of working environment | |||||
| Shell material | Metal | ||||
| Protection grade | IEC standard IP54 | ||||
Wiring diagram
Wiring diagram