Description
Product overview
18GM series ultrasonic sensor is M18 cylindrical threaded non‑contact ultrasonic time‑of‑flight ranging sensor, specially optimized for chemical flux, corrosive liquid tank level and fluid‑related detection. It measures distance by transmitting ultrasonic pulse and receiving echo signal, immune to liquid color, transparency, slight foam and vapor interference. Built‑in temperature compensation, teach‑in setting function, reverse‑polarity and short‑circuit protection. Nickel‑plated brass housing provides good corrosion resistance for chemical workshop environment. Multi‑color LED shows power status, echo signal and fault alarm. Multiple output versions available. Widely used for chemical agent tank monitoring, flux liquid level detection, sewage treatment, industrial automation object detection and packaging machinery
‑ M18 cylindrical nickel‑plated brass threaded housing, suitable for chemical workshop corrosive environment
‑ Non‑contact ultrasonic echo‑time‑of‑flight principle, not affected by liquid color and transparency
‑ Built‑in temperature compensation, effectively eliminate temperature drift error
‑ Support teach‑in distance setting via signal wire, convenient on‑site parameter configuration
‑ Multiple output options: NPN / PNP switching output, 4‑20 mA / 0‑10 V analog, IO‑Link, RS485 Modbus‑RTU
‑ Multi‑color LED indicator for power supply, echo signal and fault warning
‑ IP67 protection grade, dust‑proof and splash‑proof
‑ Multiple measuring range options, small blind zone, high repeat accuracy
‑ Reverse‑polarity & short‑circuit protection, stable performance for harsh industrial conditions
‑ CE certified, ideal solution for chemical flux liquid‑level & industrial object detection
| Model | UB500-18GM75--V15 UB500-18GM75-U-V15 |
UB1000-18GM75--V15 UB1000-18GM75-U-V15 |
|
| Detection range | 30-500 mm | 70….1000 mm | |
| Adjustment range | 50…500 mm | 90…1000 mm | |
| Blind Zone | 0…30 mm | 0--70 mm | |
| Standard target plate | 100 mmx100 mm | 100mmx100mm | |
| Transducer Frequency | Approx. 380kHz | approx. 205 kHz | |
| Response Delay | Approx. 50ms | approx. 125 ms | |
| LED Yellow | Always on: Object within detection range Blinking:Target detected in the set state. |
Always on: Object detected within the detection range Blinking: Target detected in the set state |
|
| LED Red | Always on:Error Flashing: Target not detected in the set state. |
Always on:Error Blinking: Target not detected in set state |
|
| Operating Voltage | I | 10...30 V ripple 10 %PP | 10...30 V ripple 10 %PP |
| U | 15...30 V ripple 10 %PP | 15...30 V ripple 10 %PP | |
| No-load current | I | ≤45 mA | ≤45 mA |
| U | ≤50 mA | ≤50 mA | |
| Output Type | I | 1 analogue output 4...20 mA | 1 analogue output 4...20 mA |
| U | 1 analogue output 0...10 V | 1 analogue output 0...10 V | |
| Resolution | I | 0.13 mm at maximum detection distance | 0.35 mm |
| U | 0.11 mm at maximum detection distance | 0.35 mm | |
| Characteristic curve deviation | Taxi 1% of full scale value | Taxi 1% of full scale value | |
| Repeatability | ±0.1% of full scale value | ±0.1% of full scale value | |
| Load Impedance | I | 0...300 Ohm | 0...300 Ohm |
| U | >1 kOhm | >1 kOhm | |
| Temperature Drift | 1.5% of full scale value | 1.5% of full scale value | |
| Input Type | TEACH-N input | TEACH-N input | |
| Lower limit of detection range A1:-UB...+V1 | Lower limit of detection range A1:-UB...+V1 | ||
| Upper limit of detection range A2:+4V...+UB | Upper limit of detection range A2:+4 V...+UB | ||
| Input impedance:>4.7KΩ TEACH-IN pulse:>1s | Input impedance:>4.7KΩ TEACH-IN pulse:>1s | ||
| Standard | IEC/EN60947-5-2 | IEC/EN60947-5-2 | |
| Ambient Temperature | -25°C to +70°C (248...343K) | -25°C to +70°C (248...343K) |
Wiring diagram